Common problem

Injection molding machine common fault treatment method

2024-10-07 09:33:09 Injection molding machine

First, the oil pump motor and oil pump start, but not pressure.

1. The proportional valve on the oil pump is loose or the coil is burned - check whether the proportional pressure valve is energized.

2. Impurities block the oil port of the proportional pressure valve on the oil pump -- remove the proportional pressure valve to 

remove impurities.

3. The pressure oil is unclean, the debris accumulates on the surface of the oil filter, preventing the pressure oil from entering the 

pump - clean the oil filter and replace the pressure oil.

4. Oil leakage inside the oil pump, caused by too long use, internal loss or pressure oil unclean damage - repair or replace the oil 

pump.

5. Oil spillage barrels, oil pipes and joints - eliminate leakage areas.

6. Oil business card printing dead - check whether the oil spool activity is normal.

injection mould


Second, the melting tube temperature can not be controlled

1. If the temperature cannot be controlled, check whether the contact of the electric heating contactor is sticky, and whether the wire of the thermocouple is loose or damaged.

2. If the temperature cannot rise, check whether the electric heating air switch in the electric box is off, whether the contactor and relay are drawn, whether there is voltage, whether the insurance is burned out, and whether the heating ring is burned out.

3. Check whether the thermometer is damaged.


Three, no mold locking

1. Whether the front opening safety door has been closed, whether the stopper of the safety door has been pressed and loosened 

by the safety door, and whether the wiring is loose or damaged.

2. The mode-locked solenoid coil may have moved inside the valve and stuck the spool -- clean or replace the mode-locked mold 

opening control valve.

3. Direction valve may be out of position - Clean the direction valve.

4. The thimble cannot be returned to reset -- check whether the thimble works normally.

5. Check whether the origin of the mode-locking and mode-opening electronic ruler of the computer controller has changed and 

whether the mode-locking position has terminated.

6. Check whether the pressure gauge works.

7. Press the mode-locking key to see whether the display displays mode-locking signals or other signals and alarms.

8. Check whether the position, speed and pressure of the mold lock are adjusted normally.

9. Check whether the clamping piston rod is broken.


Four, do not shoot glue

1. The coil of the injection solenoid system may have been burned, or there are foreign objects entering the direction valve, and the 

valve core is stuck to move - clean or replace the injection valve.

2. The pressure is too low -- adjust the pressure of the high jet glue.

3. The temperature of injection molding is too low - adjust the thermometer to increase the temperature to the required point, such 

as adjusting the thermometer still can not increase the temperature, check whether the electric heater and fuse are burned out

Or loose break, if broken, timely replacement.

4. The injection combination valve opening system connection is loose or poor contact - the combination switch wire connector is 

properly connected.


Fifth, the glue screw rotates, but the rubber material does not enter the barrel

1. The melt back pressure is too high, the back pressure valve is damaged or improperly adjusted -- adjust or replace the melt back 

pressure valve.

2. Insufficient water transport, so that the temperature is too high, so that the rubber particles into the screw is blocked - adjust the 

water transport, take out the bonded rubber block. See if the water conveyor is blocked or has no cooling water

3. There is no material in the bucket - add material.

4. Whether the melt tube temperature is too high.


Six. The shooting platform does not move

1. The moving limit travel switch of the shooting platform is pressed by the adjusting ram - adjust.

2. The coil of the shooting platform moving solenoid valve may be burned or there are foreign objects entering the direction valve 

stuck in the spool to move - clean or replace the solenoid valve.

3. Check the forward speed of the shooting platform and whether the pressure is improperly adjusted.

4. Check the 1/0 board, the direction valve output voltage (DC+24V) is normal, if not normal, check the corresponding output 

transistor or relay is damaged.

5. Press the station key to check whether the computer display displays the signal in front of the station, or other signals and alarms.

6. Check whether the pressure gauge works.

injection mould


Home
Product
News
Contact
主站蜘蛛池模板: 国产精品美女久久久久久久久 | 人人玩人人添人人澡欧美| 亚洲中文欧美在线视频| 国产精品自产拍在线18禁| 亚洲综合一区二区三区无码| 国产麻豆精品精东影业av网站| 国产成人无码一区二区在线观看| 成在人线av无码免费看网站直播| 久久久久久人妻精品一区| 特黄大片又粗又大又暴| 国产精品美女久久久9999| 午夜无码免费福利视频网址| 97成人碰碰久久人人超级碰oo| 国产精品天堂avav在线| 在线高清亚洲精品二区| 色琪琪av中文字幕一区二区| 国产亚洲精品麻豆一区二区| 粗大的内捧猛烈进出看视频| 欧美大屁股喷潮水xxxx| 久久人爽人人爽人人片av| 亚洲a∨无码男人的天堂| 久久久久影院色老大2020| 日本一道高清一区二区三区| 99久热re在线精品视频| 97爱爱| 精品深夜av无码一区二区| 97人妻天天爽夜夜爽二区| 无码国产精品一区二区vr老人| 色翁荡熄又大又硬又粗又视频 | 亚洲国产精品久久电影欧美| 经典三级欧美在线播放| 国产成人a∨激情视频厨房| 久久不见久久见免费影院视频观看 | 久久久久人妻一区精品性色av| 在线 亚洲 国产 欧美| 97色精品视频在线观看| 无码国产精品一区二区免费式直播 | 无码人妻丝袜在线视频| 亚洲熟妇久久国内精品| 国产成人拍拍拍高潮尖叫| 小??伸进???网|